FTDX1200 Operating Manual Page 125

MENU MODE Cont'd

Previous Page    Index of Topics    Table of Contents    Index of Pages    Next Page

MENU ITEM DETAILS Cont'd



TX GNRL GROUP

177 TX MAX POWER
Function: Sets a transmitter outpus power level.
Available Values: 5 ~ 100 Watts
Default Setting: 100 Watts


178 EXT AMP TUNING PWR
Function: Selects a maximun output power limit for driving the input circuit of an external linear RF amplifier while tuning (while using the Remote Control function of the linear RF amplifier).
Available Values: 10, 20, 50 or 100 Watts
Default Setting: 100 Watts


179 TUNER SELECT
Function: Enable/Disable the optional FC-40 Antenna Tuner.
Available INTERNAL or EXTERNAL
Default Setting: INTERNAL

INTERNAL: The [TUNE] button will activate the internal Antenna Tuner.

EXTERNAL: The [TUNE] button will activate the optiona FC-40 Antenna Tuner.


180 VOX SELECT
Function: Selects the audio input source for triggering TX during VOX operation.
Available Values: MIC or DATA
Default Setting: MIC

MIC: The VOX function will be activated by the microphone audio input.

DATA: The VOX function will be activated by data audio input port (pin 1) of the RTTY/PKT jack.


181 VOX GAIN
Function: Adjusts the "VOX" Gain on the SSB, AM and FM modes.
Available Values: 0 ~ 100
Default Setting: 50


182 VOX DELAY
Function: Adjusts the "VOX" Delay (receiver recovery) time on the SSB, AM or FM modes.
Available Values: 30 ~ 3000 msec (10 msec/step)
Default Setting: 500 msec


183 ANTI VOX GAIN
Function: Adjusts the Anit-Vox Trip Gain, which is the level of negative AF feedback of receiver audio to the microphone, to prevent receiver audio from activating the transmitter (via the microphone) during VOX operation
Available Values: 1 ~ 100
Default Setting: 50


184 EMERGENCY FREQ TX
Function: Enables TX/RX operation on the Alaska Emergency Channel, 5167.5 kHz.
Available Values: ENABLE or DISABLE
Default Setting: DISABLE

When this Menu item is set to "ENABLE", the sopt frequency of 5167.5 kHz will be enabled. The Alaska Emergency Channel will be found between the Memory channels "P-1" and "01 (or 1-01)".

IMPORTANT: The use of this frequency is restricted to stations operating in or near Alaska, and only for emergency purposes (never for routine operations). See S 97.401(c) of the FCC regulations for details.


End of Menu Item Details
"TX GNRL Group"


AF SCOPE GROUP

185 FFT DISPLAY MODE
Function: Selects the operating mode of the Audio Scope Monitor.
Available SPECTRUM or WATER FALL
Default Setting: SPECTRUM

SPECTRUM: The Audio Scope Monitor shows the audio signal on the Spectrum display.

WATER FALL: The Audio Scope Monitor shows the audio signal on the Water Fall display.


186 FFT ATT
Function: Selects the attenuation level of the Audio Scope Monitor.
Available Values: 0, 10, or 20 dB
Default Setting: 10 dB


End of Menu Item Details
"AF Scope Group"


DECODE CW

187 CW DECODE BW
Function: Selects the bandwidth of the AFC feature.
Available Values: 25, 50, 100 or 250 Hz
Default Setting: 100 Hz


End of Menu Item Details
"Decode CW"

Cont'd Next Page "Menu Mode"

Previous Page    Index of Topics    Table of Contents    Back to Top    Index of Pages    Next Page